- About Us
- Departments
- Engineering & Planning
- Construction
- Standard Specifications and Details
Standard Specifications and Details
To be automatically notified of any changes to the specifications or details, please visit the Notify Me page and subscribe to SID Standards.
Standard Specifications:
- 00700 – General Conditions
- 01100 – General Requirements
- 01570 – Temporary Erosion and Sediment Control
- 02200 – Site Preparation
- 02300 – Earthwork
- 02446 – Directional Boring
- 02511 – Lined Canal & Reservoirs
- 02512 – Existing Canal Grading and Concrete Lining
- 02513 – Irrigation Pipelines: Rubber Gasketed Reinforced Concrete Pipe (RGRCP)
- 02514 – Irrigation Pipelines: Polyvinyl Chloride (PVC)
- 02515 – Pressurized Non-Potable Water Systems
- 02516 – Domestic Potable Water Systems
- 02517 – High-Density Polyethylene (HDPE) Pipe and Fittings (4” Diameter and Greater)
- 02518 – Irrigation Pipeline Lining (Cured-In-Place Pipe)
- 02519 – Conductive Trace Wire for Nonmetallic Pipe Installations
- 02520 – Gravel Packed Water Well
- 02600 – Drainage Pipelines
- 02730 – Gravel Road Surfacing
- 02740 – Asphaltic Concrete Paving
- 02770 – Extruded Concrete Curb and Gutter
- 02820 – Chain Link Fencing
- 03300 – Cast-In-Place Concrete
- 03310 – Concrete Pipe Structures
- 03315 – Structural Concrete
- 04820 – Concrete Masonry Fencing
- 05500 – Miscellaneous Metal Work
- 05530 – Canal Trash Screens and Lifenets
- 11210 – Motor Driven Pumping Units
- 11285 – Irrigation Gates and Valves
- 13400 – Supervisor Control and Data Acquisition (SCADA)
- 16010 – Basic Electrical materials and Methods
- 16100 – Wiring Methods
- 16400 – Distribution and Grounding
- 16500 - Lighting
Construction Details:
- All Standard Detail Sheets (7 MB)
- W-0 Standard Detail Index Pg 1 of 2
- W-0.1 Standard Detail Index Pg 2 of 2
- W-1 Trench Details for Polyvinyl Chloride Pipe (PVC)
- W-2 Water Main & Sewer Pipeline Separation Detail
- W-2.1 Water Main & Non-Potable Pipeline Separation
- W-3 Fittings & Thrust Blocks for Horizontal Bends and Tees
- W-4 Fittings & Thrust Blocks for Vertical Downward Bends
- W-5 Fittings & Thrust Blocks for Vertical Upward Bends
- W-6 “Cut-In” Tee or Cross Detail for Lateral Connection
- W-7 Fire Hydrant Detail
- W-8 Fire Hydrant Installation for Developed Areas – Attached Sidewalk
- W-8.5 Fire Hydrant Installation for Developed Areas – Detached Sidewalk
- W-9 Fire Hydrant Installation for Open Areas
- W-10 Traffic Box and Valve Detail
- W-11 ¾” - 1” Meter Connection
- W-11.5 ¾” - 1” Meter Connection with Fire Protection
- W-12 ¾” - 1” Double Meter Connection
- W-12.5 Multiple Meter Connection
- W-13 1 ½” - 2” Meter Connection
- W-13.2 3" and Larger Meter Connection
- W-13.5 Typical M&I Meter Information
- W-14 Sampling Station (Type I)
- W-14.1 Sampling Station (Type II)
- W-15 Blow Off Assemblies
- W-16 Air Release Valve Assembly
- W-17 ¾” - 2” Reduced Pressure Backflow Preventer Installation
- W-18 Reduced Pressure Backflow Preventer Protective Enclosure
- W-19 3” - 10” Reduced Pressure Backflow Preventer Installation
- W-20 Double Check Detector Assembly Installation
- W-20.5 Guard Post (Bollard) Detail
- W-21 PVC Pipe Connection to Existing Concrete Structure or Turnout Pot
- W-22 PVC Pipe Connection with Metering Well to Existing Concrete Structure or Turnout Pot
- W-22.5 Typical Waterman C-10 Canal Gate Installation
- W-23 Steel Stub Fabrication Detail for PVC to Concrete Connection
- W-23.5 Concrete Thrust Blocks for PVC Horizontal Bends (AG Pipelines)
- W-23.6 Concrete Thrust Blocks for PVC Vertical Downward Bends (AG Pipelines)
- W-23.7 Concrete Thrust Blocks for PVC Vertical Upward Bends (AG Pipelines)
- W-24 Typical Alfalfa Valve Turnout for an “Open” Pipeline
- W-24.3 Typical AG Turnout with Propeller Meter
- W-24.4 Typical AG Turnout with Mag-Meter
- W-24.5 Typical AG Turnout with Open-Flow Meter
- W-24.6 Metered Connection to a Long Turnout or an Existing Private Pipeline
- W-24.7 Typical AG & NPW Meter Information (Low Flow)
- W-24.8 Typical AG & NPW Meter Information (Normal Flow)
- W-25 Air & Vacuum Valve for Closed PVC Pipelines 18” and Less in Diameter
- W-26 Air & Vacuum Valve for Closed PVC Pipelines 21” and Greater in Diameter
- W-26.5 Safety Screen
- W-27 Air Vent for “Open” PVC Pipelines
- W-27.3 Blow Off Assembly for Large Diameter PVC Pipelines
- W-27.5 Spill Structure
- W-27.7 4" Wharf Hydrant
- W-28 Trench Details for Rubber Gasket Reinforced Concrete Pipe (RGRCP)
- W-29 Concrete Pipeline Connection Block
- W-30 RGRCP: Concrete Thrust Blocks for Horizontal Bends
- W-30.4 RGRCP: Concrete Thrust Blocks for Horizontal Steel or Ductile Iron Bends
- W-30.5 RGRCP: Concrete Thrust Blocks for Vertical Downward Bends
- W-30.6 RGRCP: Concrete Thrust Blocks for Vertical Upward Bends
- W-31 RGRCP: Field-Fabricated Miter Bends
- W-32 RGRCP: 24” Manhole – Type 1&1A (Open Field: Isolated or Untraveled)
- W-33 RGRCP: 24” Manhole – Type 2&2A (Open Field: Inhabited or Traveled)
- W-34 RGRCP: 24” Manhole – Type 3&3A (Surfaced Area: Depth of Cover Greater Than 30”)
- W-35 RGRCP: 24” Manhole – Type 4&4A (Surfaced Area: Depth of Cover Less Than 30”)
- W-36 RGRCP: Miscellaneous Manhole Details
- W-36.5 RGRCP: Blow Off Assembly
- W-37 RGRCP: Concrete Structure Connection
- W-38 RGRCP: New Pipeline AG Turnout
- W-39 RGRCP: Existing Pipeline AG Turnout
- W-39.5 Typical Arched Culvert Installation
- W-39.7 Typical Round Culvert Installation
- W-40 Concrete Protection Slab over Existing S.I.D. Pipeline
- W-41 Cased utility Crossing Over Existing S.I.D. Pipeline
- W-42 Utility Crossing Under Existing S.I.D. Pipeline with Concrete Protection Slab
- W-43 Cased Utility Crossing Under Existing S.I.D. Pipeline
- W-44 Cased Utility Crossing Lined Canal
- W-45 Open-Cut Utility Crossing Earthen Canal
- W-45.5 Typical Safety Ladder for Concrete Lined Canals
- W-45.6 Typical Weep Valve Installation
- W-45.7 Typical Concrete Lining for an Existing Canal
- W-46 Typical Chain Link Fencing
- W-47 Typical Single Swing Gate
- W-48 Typical Automatic Single Swing Gate for Undeveloped Areas
- W-49 Typical Automatic Single Swing Gate for Developed Areas
- W-50 Typical Single Rolling Gate
- W-51 Typical Driveway Approaches and Bridge Crossing
- W-52 Typical Concrete Curb and Gutter
Contact Us
-
If you have questions or need assistance please contact:
Uriel Romero
Civil Engineer
707-455-4045